Quartz Gauge
Panther’s Hellseeker Hybrid Quartz Probe is a highly precise, down hole electronic pressure/temperature memory gauge. It is designed with leading technology that is unmatched by any other product currently available.
Panther Probe uses Quartzdyne technology that provides our gauge with high resolution, reproducibility, and long-term stability combined with the ruggedness needed for successful long term well testing.
Our new Hellseeker Hybrid tool is a culmination of 18 years experience in pressure recorder design and hybrid technology. We have taken out all the typical failure mechanisms in printed circuit design using bare die (no plastic encapsulation) and have sealed our ceramic substrate in a hermetic module. We then mount our hybrid module in a secondary pressure proof housing using a connector rated to 20,000 psi and 200 degrees Celcius.
Pressure | |
---|---|
Accuracy (% of full scale) | 0.02 |
Resolution (% of full scale) | 0.00006 or 0.02 kPa 35000 kPa gauge |
Repeatability (% of full scale) | < 0.01 error |
Available Sensor | 3.5 mPa - 138 mPa (5,000 psi - 20,000 psi) |
Temperature | |
Accuracy | 0.2 ° C |
Resolution | 0.01 ° C |
Operating Temperature | 190 ° C |
Capacity | |
Number of Data Sets | 1,000,000 sets |
Battery Capacity (days) | 225 days @ 30 seconds |
Physical | |
Outside Diameter | 1.32 inch (3.35 cm) | 1.25 inch (3.18 cm) |
Length | 22 inch (55.88 cm) | 24.6 inch (62.48 cm) |
Tranducer Type | Quartzdyne quartz resonator |
Material | Hastelloy C-276 and Incolloy 718 / 925 |
Power Requirements | |
Voltage | 3V |
Source | Lithium Battery |
Battery Type | 1 CC Cell Pack |
Communication Type | |
Type | USB |
Silicon Probe
Panther’s Silicon Probe is an accurate, down hole electronic measuring memory probe.
Panther Probe uses an exclusive silicone-crystal technology that provides a gauge with accuracy, reliability and stability for successful well testing.
Our Silicone probe comes assembled, pre-programmed and ready to go. The software provided is easy to use for changing programs and/or downloading data.
Panther Silicone Probe is designed for long term testing and is very cost efficient to operate.
Pressure | |
---|---|
Accuracy (% of full scale) | 0.03 (typical 0.025) |
Resolution (% of full scale) | 0.00006 or 0.02 kPa 35000 kPa gauge |
Available Sensors | 1.0 mPa - 103 mPa (150 psi - 15,000 psi) |
Temperature | |
Accuracy | 0.5 ˚ C |
Resolution | 0.01 ˚ C |
Operating Temperature | 150 ˚ C |
Capacity | |
Number of Data Sets | 1,000,000 sets |
Battery Capacity - Single Pack | 28 days @10 sec samples | 132 days @ 60 |
Physical | |
Outside Diameter | 0.5 inch (1.27 cm) |
Length | 10 inch (25.4 cm) or 12.25 inch (31.11 cm) |
Tranducer Type | Silicon Crystal |
Material | Incolloy 625 / 718 |
Power Requirements | |
Voltage | 3V |
Source | Lithium Battery |
Battery Type | AAA or 2 AAA Pack |
Communication | |
Type | USB |
Pressure | |
---|---|
Accuracy (% of full scale) | 0.03 |
Resolution (% of full scale) | 0.00006 or 0.02 kPa 35,000 kPa gauge |
Available Sensors | 1.0 mPa - 103 mPa (150 psi - 15,000 psi) |
Temperature | |
Accuracy | 0.5 ˚ C |
Resolution | 0.01 ˚ C |
Operating Temperature | 150 ˚ C |
Capacity | |
Number of Data Sets | 1,000,000 sets |
Battery Capacity - Single Pack | 28 days @10 sec samples | 132 days @ 60 |
Battery Capacity - Double Pack | 56 days @ 10 sec samples | 364 days @ 60 |
Physical | |
Outside Diameter | 0.625 inch (1.59 cm) |
Length | 11.5 inch (29.21 cm ) | 12.75 (32.29 cm) |
Tranducer Type | Silicon Crystal |
Material | Incolloy 625 / 718 |
Power Requirements | |
Voltage | 3V |
Source | Lithium Battery |
Battery Type | AAA or 2 AAA Pack |
Communication | |
Type | USB |
Pressure | |
---|---|
Accuracy (% of full scale) | 0.03 |
Resolution (% of full scale) | 0.00006 or 0.02 kPa 35,000 kPa gauge |
Available Sensors | 1.0 mPa - 103 mPa (150 psi - 15,000 psi) |
Temperature | |
Accuracy | 0.5 ˚ C |
Resolution | 0.01 ˚ C |
Operating Temperature | 150 ˚ C |
Capacity | |
Number of Data Sets | 1,000,000 sets expandable to 4,000,000 |
Battery Capacity | 63 days @ 10 sec samples | 303 days @ 60 |
Physical | |
Outside Diameter | 0.75 inch (1.91 cm) |
Length | 10.5 inch (26.67 cm) |
Tranducer Type | Silicon Crystal |
Material | Hastelloy C-276 & Incolloy 718 / 925 |
Power Requirements | |
Voltage | 3V |
Source | Lithium Battery |
Battery Type | 1 “AA” Cell Pack 1.6 Ah |
Communications | |
Type | USB |
Pressure | |
---|---|
Accuracy (% of full scale) | 0.03 |
Resolution (% of full scale) | 0.00006 or 0.02 kPa 35,000 kPa gauge |
Available Sensors | 1.0 mPa - 103 mPa (150 psi - 15,000 psi) |
Temperature | |
Accuracy | 0.5 ˚ C |
Resolution | 0.01 ˚ C |
Operating Temperature | 150 ˚ C |
Capacity | |
Number of Data Sets | 1,000,000 sets expandable to 4,000,000 |
Battery Capacity | 104 days @ 10 sec | 215 days @ 60 sec |
Physical | |
Outside Diameter | 0.875 inch (2.16 cm) |
Length | 12 inch (30.48 cm) |
Tranducer Type | Silicon Crystal |
Material | Hastelloy C-276 & Incolloy 718 / 925 |
Power Requirements | |
Voltage | 3V |
Source | Lithium Battery |
Battery Type | 1 AA Cell Pack 1.6 Ah |
Communication | |
Type | USB |
Pressure | |
---|---|
Accuracy (% of full scale) | 0.03 (typical 0.025) |
Resolution (% of full scale) | 0.00006 or 0.02 kPa 35000 kPa gauge |
Available Sensors | 1.0 mPa - 103 mPa (150 psi - 15000 psi) |
Temperature | |
Accuracy | 0.5 ˚ C |
Resolution | 0.01 ˚ C |
Operating Temperature | USB Board 150 ˚ C |
Capacity | |
Number of Data Sets | 4,000,000 sets |
Battery Capacity - USB Board | 375 days @ 5 sec - 1200 days @ 60 sec |
Physical | |
Outside Diameter | 1.25 inch (3.18 cm) |
Length | 18 inch (45.7 cm) |
Tranducer Type | Silicon Crystal |
Material | Hastelloy C-276 & incolloy 718 / 925 |
Power Requirements | |
Voltage | 3V |
Source | Lithium Battery |
Battery Type | 1 sub CC pack |
Communications | |
Type | USB |
Pressure | |
---|---|
Accuracy (% of full scale) | 0.03 (typical 0.025) |
Resolution (% of full scale) | 0.00006 or 0.02 kPa 35000 kPa gauge |
Available Sensors | 35 mPa - 138 mPa (5000 psi - 20000 psi) |
Temperature | |
Accuracy | 0.2 ˚ C |
Resolution | 0.01 ˚ C |
Operating Temperature | Short term capability - 175 ˚ C (1 week or less) |
Operating Temperature | Long term capability - 150 ˚ C |
Capacity | |
Number of Data sets | 4,000,000 sets |
Battery Capacity | 280 days @ 10 sec, 415 days @ 60 sec |
Physical | |
Outside Diameter | 1.32 inch (3.35 cm) |
Length | 18 inch (45.7 cm) |
Tranducer Type | High Temperature, Low Drift - Silicon Crystal |
Material | Hastelloy C-276 & Incolloy 718 / 925 |
Power Requirements | |
Voltage | 3V |
Source | Lithium Battery |
Battery Type | 1 CC pack |
Communication | |
Type | USB |
Panther’s Quartz Probe is a highly precise, down hole electronic pressure/temperature memory probe. The Panther Probe is designed with the leading technology that is unmatched by any other product currently available.
Panther Probe uses Quartzdyne technology that provides our gauge with high resolution, reproducibility, and long-term stability combined with the ruggedness needed for successful long term well testing.
Our Quartz probe comes assembled, pre-programmed and ready to go. The software provided is easy to use for changing programs and/or downloading data.
Panther Quartz Probe is designed for long term testing and is very cost efficient to operate.
Pressure | |
---|---|
Accuracy (% of full scale) | 0.02 |
Resolution (% of full scale) | 0.00006 or 0.02 kPa 35000 kPa gauge |
Repeatability (% of full scale) | < 0.01 error |
Available Sensors | 3.5 mPa - 138 mPa (5,000 psi - 20,000 psi) |
Temperature | |
Accuracy | 0.2 ° C |
Resolution | 0.01 ° C |
Operating Temperature | 150 ° C |
Capacity | |
Number of Data Sets | 3,000,000 sets |
Battery Capacity (days) | 73 @ 5 second | 209 @ 60 seconds |
Physical | |
Outside Diameter | 1.32 inch (3.35 cm) | 1.25 inch (3.18 cm) |
Length | 22.2 inch (56.5 cm) | 26.6 inch (67.5 cm) |
Tranducer Type | Quartzdyne quartz resonator |
Material | Hastelloy C-276 and Incolloy 718 / 925 |
Power Requirements | |
Voltage | 3V |
Source | Lithium Battery |
Battery Type | 1 CC Pack |
Communication | |
Type | Parallel to USB |